All templates
Structural SteelCommercial

Structural Steel Erection Inspection & Test Plan

ITP for on-site erection of structural steelwork covering crane operations, temporary bracing, alignment, plumb checks and connection completion per AS 4100.

13 checklist items
3 hold points
2 witness points
Use this template, it's free

Used on live Australian projects

DynafixTreu Construct
Read their stories

Checklist Preview

Pre-Erection Checks

Requires sign-off
P/F
Erection sequence plan reviewed
P/F
Base plates and anchor bolts surveyed
Hold
P/F
Grout bed levels set to tolerance
P/F
Members identified and match delivery schedule

Erection Process

Requires sign-off
P/F
Crane lift plan approved
P/F
Temporary connections securing members
P/F
Column plumb within H/500 tolerance
Hold Witness
P/F
Beam levels within ±5mm tolerance
P/F
Temporary bracing installed per plan

Permanent Connections

Requires sign-off
P/F
Bolts installed and tensioned per specification
Hold
P/F
Site welding completed per WPS
Witness
P/F
Touch-up coating at connections complete
✓
As-built survey completed

Prefer AI?

Generate a custom Structural Steel ITP in seconds

Describe your scope and our AI builds a complete ITP with hold points, witness points, and sign-off roles, tailored to your project.

Free AI ITP Generator →

Also free from the HoldPoint QA team: a structural steel supplier price list template (Excel), to check supplier invoices against with CostCode.

Ready to use this template?

Sign up, import this ITP template into your project, and start inspecting. 14 days free, no credit card required.

Get started free