All templates
Structural SteelCommercial

Bolted Connection Inspection & Test Plan

ITP for high-strength bolted connections in structural steelwork covering bolt grade verification, installation method, tension verification and slip-critical joint inspection per AS 4100.

12 checklist items
3 hold points
1 witness points
Use this template — it's free

Checklist Preview

Bolt Supply & Verification

Requires sign-off
P/F
Bolt grade markings match specification
Hold
P/F
Bolt lot certification reviewed
P/F
Bolts free from damage and corrosion
P/F
Hardened washers provided per AS 4100

Installation

Requires sign-off
P/F
Bolt holes aligned without reaming
P/F
Snug-tight condition achieved
P/F
Tensioning method per specification (TC/DI/TW)
Hold
P/F
Tightening sequence from center outward

Tension Verification

Requires sign-off
P/F
10% bolt tension audit satisfactory
Hold Witness
P/F
TC bolt spline sheared (tension-control)
P/F
Feeler gauge check on faying surfaces
P/F
All bolts installed per connection detail

Ready to use this template?

Sign up for free, import this ITP template into your project, and start inspecting. Your first project is always free.