Structural SteelCommercial
Bolted Connection Inspection & Test Plan
ITP for high-strength bolted connections in structural steelwork covering bolt grade verification, installation method, tension verification and slip-critical joint inspection per AS 4100.
12 checklist items
3 hold points
1 witness points
Checklist Preview
Bolt Supply & Verification
Requires sign-offP/F
Bolt grade markings match specification Hold
P/F
Bolt lot certification reviewedP/F
Bolts free from damage and corrosionP/F
Hardened washers provided per AS 4100Installation
Requires sign-offP/F
Bolt holes aligned without reamingP/F
Snug-tight condition achievedP/F
Tensioning method per specification (TC/DI/TW) Hold
P/F
Tightening sequence from center outwardTension Verification
Requires sign-offP/F
10% bolt tension audit satisfactory Hold Witness
P/F
TC bolt spline sheared (tension-control)P/F
Feeler gauge check on faying surfacesP/F
All bolts installed per connection detailReady to use this template?
Sign up for free, import this ITP template into your project, and start inspecting. Your first project is always free.