All templates
RoofingResidential

Roof Insulation Inspection & Test Plan

ITP for roof insulation installation covering material selection, R-value compliance, vapour barriers, clearances around services and NCC Section J energy efficiency requirements.

12 checklist items
2 hold points
Use this template — it's free

Checklist Preview

Material Verification

Requires sign-off
P/F
Insulation R-value per NCC requirements
Hold
P/F
Product CodeMark or equivalent certification
P/F
Material type per specification (batts/blankets/boards)

Installation

Requires sign-off
P/F
Full coverage with no gaps or compression
P/F
Butt joints tight with no air gaps
P/F
Clearance around downlights per manufacturer
Hold
P/F
Clearance from exhaust fans maintained
P/F
Vapour barrier installed where specified

Compliance Checks

P/F
Insulation not covering electrical cables
P/F
Access to roof space maintained
Manhole cover insulated
Aa
JV3/Section J energy assessment reference

Ready to use this template?