RoofingResidential
Roof Flashing & Guttering Inspection & Test Plan
Dedicated ITP for roof flashings and rainwater goods covering material selection, flashing integration, gutter sizing, downpipe connection and overflow provisions per AS/NZS 3500.3.
13 checklist items
2 hold points
Checklist Preview
Flashings
Requires sign-offP/F
Flashing material and gauge per specificationP/F
Step flashing at wall/roof junctionsP/F
Apron flashing dressed and sealedP/F
Penetration flashings (pipes, vents) sealed HoldPhoto
P/F
Valley flashing width per rainfall intensity zoneGutters & Downpipes
Requires sign-offP/F
Gutter profile and size per hydraulic designP/F
Gutter fall minimum 1:500 to outletsP/F
Bracket spacing per manufacturer specP/F
Downpipe size per designOverflow & Completion
Requires sign-offP/F
Overflow provisions at box gutters and sumps Hold
P/F
Downpipe connection to stormwater systemP/F
Rainhead installed and accessibleP/F
Leaf guard installed where specifiedReady to use this template?
Sign up for free, import this ITP template into your project, and start inspecting. Your first project is always free.