Curtain Wall Glazing Inspection & Test Plan
ITP for curtain wall façade systems covering mullion installation, transom alignment, glass unit installation, structural silicone application and weather seal testing per AS 2047.
13 checklist items
3 hold points
2 witness points
Checklist Preview
Framing Installation
Requires sign-offP/F
Mullion alignment plumb within tolerance Hold
P/F
Transom levels per designP/F
Bracket and anchor fixings per structural designP/F
Thermal break continuity maintainedP/F
Movement allowance per structural engineerGlazing Installation
Requires sign-offP/F
Glass type and make-up per specification Hold
P/F
Glass seated on setting blocksP/F
Structural silicone applied per manufacturer spec Witness
P/F
Pressure plates and caps installedSealing & Testing
Requires sign-offP/F
Perimeter weather seals installedP/F
Drainage and weep slots clearP/F
Hose water test satisfactory per AS 2047 Hold Witness
P/F
No visible distortion or coating defectsReady to use this template?