All templates
ElectricalResidential

Electrical Rough-In Inspection & Test Plan

Covers first-fix electrical rough-in including cable runs, conduit installation, back-box positioning and earthing continuity. Ensures compliance with AS/NZS 3000 wiring rules prior to wall lining.

17 checklist items
2 hold points
2 witness points
Use this template — it's free

Checklist Preview

Cable Installation

Requires sign-off
P/F
Verify cable types match specifications
P/F
Cable support and clip spacing compliant
P/F
Separation from other services maintained
P/F
Fire-rated penetration sealing complete
HoldPhoto
P/F
Minimum bend radius maintained

Conduit & Containment

Requires sign-off
P/F
Conduit sizing per design drawings
P/F
Conduit fixing centres compliant
Draw wire installed in empty conduits
P/F
Expansion joints provided where required

Back Boxes & Point Positions

P/F
Back-box heights per specification
P/F
Back boxes flush with finished surface
P/F
GPO layout matches electrical drawings
Witness
P/F
Switch positions per specification

Earthing & Bonding

Requires sign-off
P/F
Earth continuity test satisfactory
Hold
P/F
Earth conductor sizing compliant
P/F
Main earthing conductor connection verified
P/F
Equipotential bonding to wet areas confirmed
Witness

Prefer AI?

Generate a custom Electrical ITP in seconds

Describe your scope and our AI builds a complete ITP with hold points, witness points, and sign-off roles — tailored to your project.

Free AI ITP Generator →

Ready to use this template?

Sign up, import this ITP template into your project, and start inspecting. 14 days free — no credit card required.

Get started free